Monday, May 29, 2017

CUTTING FLUID (COOLANT-SEMI SYNTHETIC)

Semi synthetic coolant Designed to combine the best features of soluble oil and synthetic fluids. Provides better lubricity than synthetic fluids. Better visibility, as well as tramp oil rejection than soluble oil (emulsifiable oils).
Provides good results on most non-ferrous metals and is recommended, if other coolants are not practical
 Our Product:
DIACOOL CT 117SS,
Semi Synthetic Coolant Machining Fluids, packaging : 20Lt/Can

DESCRIPTION:
DIACOOL CT 117SS is semi synthetic coolant machining fluids. This product containing 10% mineral oils. DIACOOL CT 117SS is highly versatile which delivers outstanding performance for wide range of machining operations on ferrous and  non ferrous.It is formulated to be biostable, it is  means that raw material were chosen for their resistance to biological degradation thereby controlling the growth of bacteria and fungus.
Aplikasi DIACOOL CT 117SS
APPLICATION :
DIACOOL CT 117SS recommended for machining of steel, alloy steel, stainless steel, brass, cooper, and aluminium.

BENEFITS
-          Excellent cooling and lubrication.
-          Long sump life
-          Excellent settling properties.
-          Improve tool & wheel performances.
-          Good rust protection.
-          Protected system will not promote bacterial growth.
-          Less foaming
RECOMMENDED DILUTION
Grinding:
ID, OD, Centreless,
Surface, Blanchard Grinding
20 : 1 up to 30 : 1 Ratio
i.e 20 to 30 part of water : 1 part Diacool CT 117SS

Other Machining:
Drilling, Boring, Milling,
Tapping, Reaming,
Turning, and
Threading
Semi synthetic coolant after dilution


10 : 1 up to 20 :lant  1 ratio

For more details, please contact us :
PT. Aalen Chemicals Indonesia
Jl Pulobuaran III Blok G3,
Kawasan JIEP Pulogadung
Tlp : 021-46830522
Web : www.aalen.co.id
Email : aalen.chemicals@gmail.com, aalen@cbn.net.id

Wednesday, May 24, 2017

COOLANT (CUTTING OIL-FULL SYNTHETIC)

Our Product:
a. Diacool CT-80 SYN (Full Synthetic), Premium Grade, Packaging : 20Lt/Can

DIACOOL CT-80 SYN is a Synthetic Coolant Machining Fluids,
DIACOOL CT-80 SYN is a heavy duty, oil free, synthetic based machining fluids for steel and stainless steel alloys. This means that raw material were chosen for their resistance to biological degradation thereby controlling the growth of bacteria and fungus. It provides a clean, safe and pleasant working environment.

APPLICATION :
Diacool CT-80 SYN recommended for machining of steel, alloy steel,stainless steel, bronze, vanadium, cast iron, cooper and aluminium
Application of full synthetic cutting oil

BENEFITS of Diacool CT-80 SYN :
- Superior cooling and lubrication.
- Good hard water stability.
- Outstanding anti mist properties.
- Improve tool & surface finishes.
- Excellent corrosion protection.
- Protected system will not promote bacterial growth.
- Less foaming

RECOMMENDED DILUTION
Grinding:
ID, OD, Centreless,
Surface, Blanchard Grinding,
Ratio mixing;  20 : 1 up to 30 : 1 
i.e 20 to 30 part of water : 1 part Diacool CT 80

Other Machining:
Drilling, Boring, Milling,
Tapping, Reaming,
Turning, Sawing, and
Threading
 Ratio of mixing; 10 : 1 up to 20 : 1 ratio 


b. Diacool CT 983 SYN (Full Synthetic), Standard Grade, Packaging 20Lt.
 DIACOOL CT 983 SYN is synthetic based machining fluids for use on all metals, plastics, glass and composites. This product designed for machining and grinding fluid.


DIACOOL CT 983 SYN is engineered to provide total performance, whether running small individual sumps or large central systems. Formulated using today's leading chemical technologies and qualified raw materials, that contain balanced lubrication chemistries to provide optimum results.
Our raw material were chosen for their resistance to biological degradation thereby controlling the growth of bacteria and fungus. It provides a clean, safe and pleasant working environment, corrosion protection, post-processing synchronisity, low or no foam and complete aqueous compatibility.
 Full synthetic coolant after dilution
For more details, please contact us :
PT. Aalen Chemicals Indonesia
Jl Pulobuaran III Blok G3,
Kawasan JIEP Pulogadung
Tlp : 021-46830522
Web : www.aalen.co.id
Email : aalen.chemicals@gmail.com, aalen@cbn.net.id

Friday, March 3, 2017

COAGULATION AND FLOCULATION IN A WASTE WATER TREATMENT

Coagulated, coagulating : to change from a fluid into a thickened mass; curdle; congeal.

Our Product :
DIACOG 70
Coagulation Agent for Waste Water Treatment

Packing : @20 Kg/can
The DIACOG 70 treatment has been formulated for coagulation in waste water treatment process. DIACOG 70  is work in conjunction with floculation agents (DIAFLOC 100) to destabilized particles together into larger aggregates so that they can be more easily separated from the water. Diacog 70 and Diafloc 100 are generates a floating, high solids sludge which is able to be removed from the water by sedimentation and/or filtration. 

APPLICATION
  1. Diacog 70 and Diafloc 100 conjuction with pH of waste water treatment, before using these product, cek pH waste. 
pH 7-8 :                                                    Chemical Feed Rate into Booth Water:
DIACOG 70                                                4 Liter, flow with the wind 5-10 minutes
DIAFLOC 100                                             6 Liter, flow with the wind 5-10 minutes

pH 9 :                                                                    Chemical Feed Rate into Booth Water:
DIACOG 70                                                5 Liter, flow with the wind 5-10 minutes
DIAFLOC 100                                             7 Liter, flow with the wind 5-10 minutes

pH 10 :                                                      Chemical Feed Rate into Booth Water:
DIACOG 70                                                6 Liter, flow with the wind 5-10 minutes
DIAFLOC 100                                             8 Liter, flow with the wind 5-10 minutes

b.     If flock have been formed,  stand for ±10-15 minutes, to separate between the sludge with water
c.     After appearance of the water is clear, filtration sludge and put in packaging (Tank or rafia bag).

DIA ADDITIVE pH                               To adjust pH

CONTROLS
-          pH with pH paper or pH meter
-          Turbidity with turbidity meter.
-          Jar Test
            
turbiditymeter dan alat untuk Jar Test pada pengecekan flok di lapangan.


pH Control:
NEUTRALIZER is added to keep the pH of the water circulation system.

Coagulation:
DIACOG 70 is the primary coagulant chemical in this process. This material is conjuction and activated by the DIAFLOC 100, therefore the ratio between the two chemicals in solution is critical to proper coagulation.

Flotation:
DIAFLOC 100, Flocculent is added to enhance floatation of the sludge and improve dewatering in a floatation cell, that produces a micro floc which actively interacts to produce a high solid floc in waste water system. 

Result : 2 phase of Waste --> Sludge will be drying and send to PPLI

For more details, please contact us :
PT. Aalen Chemicals Indonesia
Jl. Pulobuaran III Blok G3,
Kawasan JIEP Pulogadung
Tlp : 021-46830522
Website : www.aalen.co.id 
Email : aalen.chemicals@gmail.com, aalen@cbn.net.id